Evergreen Telemetry
 
 

General

Services include repair and NIST-traceable calibration of Evergreen Telemetry products. Only Wireless Sensing Modules are calibrated. The recommended period is two years. The Wrist Reporter is a digital device optimized for display and storage—it has no role in measurement. However, it is advisable to submit the Wrist Reporter along with the Sensing Modules so its software can be updated.


Shortridge Instruments ADM’s are calibrated for pressure, temperature, velocity, and airflow. Readings at setpoints are compared to NIST-traceable standards. No adjustments or repairs are performed.


Instruments and Setpoints

The key calibration tool is the Setra 869, the most accurate

low-pressure calibrator in the world. The Setra 869 boasts an

accuracy of +/- 0.0002 in wc for its lowest range. For velocity

and flow tests, our VFD-controlled fan serves three test stations

through more than 60 feet of duct with flow straighteners and

orifice plates. See the nearby table for nominal test points.

Additional test points may be added for a small fee.


Barometric Pressure (in Hg):  14, 29, 32.

Differential Pressure (in wc):  10, 2, .5, .05, -10, -.05.

Temperature (°F):  33, 75, 140.

Velocity (FPM):  100, 500.

Airflow (CFM):  100, 500.  (Only performed if capture hood is provided).



Turnaround Time Guarantee

Instruments will spend less than two business days at Evergreen Telemetry.  For instance, if received on Monday, we will ship by Wednesday at the latest.  If we miss that milestone, the calibration service fee will not be charged.


Prices

Discounts are applied when multiple instruments are received at the same time from the same customer due to time saved on setup and documentation.


Pressure Sensing Module: pressure/velocity/flow*.........................$350

Temperature ...................................................................................$135

Humidity (Incl NEW Sensor Chip)...................................................$165

Shortridge ADM...............................................................................$475

*Note: Flow tests are only performed if capture hood is provided.


PROCEDURE TO ORDER CALIBRATION

No RMA is required. Ship to factory address below. Send email to address below listing submitted meters by type and serial number.

Instrument Calibration  

Instrument Calibration Services
NOW AVAILABLE

Copyright 2016  Evergreen Telemetry. All rights reserved      602-574-6192    i    624 S. Perry Ln., #102, Tempe, AZ 85281

Home   I  About   I  Wrist Reporter   I  Shortridge   I  Air Pressure   I  Water Pressure   I   TAB Kit   I  Capture Hoods   I  Calibration   I  T&H   I  Testimonials   I  Downloads   I Links   I  FAQs   I  Contact

(602) 574-6192

624 S. Perry Ln., #102

Tempe, AZ 85281

The Ultimate TAB Toolkit

Instrument Calibration Services
NOW AVAILABLECalibration_files/Pricing%20and%20Data_Aug_2016.pdfCalibration_files/DATASHEET__Sheets_1-8.pdfshapeimage_1_link_0
 
Evergreen Telemetry